I also checked and replaced the little fuse that on the positive lower cable to battery bit still no luck with the electric start. If this is causing problems, you have a simple solution available. 3 17 comments Best Add a Comment When fuel sits for a long period of time, it degrades. About Us - Affiliate Disclosure - Terms and Conditions - Privacy Policy, How to Fix a Kohler Courage XT-7 thats Not Starting. This usually takes place in the jets and it is not a serious problem. Always remove the spark plug wire and wait for the engine to cool. Check both tanks to make sure they are not your problem. You will find that the battery drains at a much faster rate. Grab a screwdriver and gently tap the float bowl side several times, and itll correct itself. That is a good deal especially since the Predator model is said to be very quiet and performs beyond expectations. The first would be the drain plug. Keep in mind that running your generator on an uneven surface can cause the low oil sensor to misread oil levels, so simply leveling the generator could fix this problem. Unplug a few items from your electrical system. Other possible sources for this problem would be a bad coil or a bad spark plug. Check for sticking valves, or blockages. Youll also want to look for items that can restrict airflow or spark. Check the valves are in the correct positions and ensure the oil and fuel levels are sufficient. Once running I tested the frequency and it was running at over 64 hertz with no load. Follow all safety instructions provided in your equipment operators manual before diagnosing, repairing, or operating. The good news is most portable Predator generators with an electric start have a manual starter recoil installed to pull-start it to get it running. It has to be just right for the generator to work smoothly. Low ethanol and ethanol-free fuel are best. Flooded. There are a number of ways that your generator can struggle to switch on. Either through the on/off switch, which runs because of the battery, or manually. Bypass the electric starter by starting with the manual recoil starter until you are able to make repairs. These are indications the solenoid may be bad. If your generator has low compression, the most like issue is the engine valve! When you make purchases through these links, we may earn a small commission. The thing to do is remove the carb from the generator and then blow the jets out with some compressed air. Removed the bad fuel and cleaned up the carb. Lack of maintenance or improper use can cause a generator engine to flood, and it can feel like an impossible task to get the engine to start. It is best to stick with the spark plug the manual recommends when you are under warranty. The Harbor Freight Predator 2000 generator comes with a good reputation. Rotate the ESC Throttle or Economy Switch button to the Off position. A carburetor is used on the generator to regulate the amount of gas that is mixed with air for combustion. A starter solenoid goes bad when the internal spring gets weak or the copper plate begins to corrode. This is because the carburetor bowl gasket may fail to seal properly or internal parts will stick allowing too much fuel into the bowl and causing it to overflow. A bad choke may also cause this problem. Replace the fuel lines. Not 2 though. A narrow filter is inserted in the fuel line or fuel component. (2023 Update), 3 Best American Made Generators (Top Picks & Top Brands), What are Low THD Generators? Gas can begin to break down and become less effective as soon as 30 days after purchase. SOLUTION: Check the voltage of the battery and charge it if it is weak. The regulator plays an important role in the generator's ability to charge the battery. That is an interesting one. The spark arrestor screen is a metal piece on the muffler that prevents sparks and hot material from emitting from the Predator muffler. Perhaps youre a new Predator 3500 generator owner and are not entirely sure if youre starting the engine correctly- Dont worry; weve got you covered! Fill it with fresh fuel and a fuel additive like. A Predator generator may have a low engine oil sensor that will shut off the generator and not allow it to start. A metal tank can develop a rust hole. Just keep in mind that its maximum wattage output is 2000 watts. Fuel calves are part of the inner fuel system in your generator. Disconnect all devices and loads from the Predator 3500 generator. Even though it is cheaper than other famous name brands for generators, it seems to work well and perform up to and beyond expectations. Remove the access panel on the right side of the generator. Squeeze excess water out of the filter and allow it to completely dry. Clean the carburetor and replace any damaged parts. Unscrew the bolt on the left side of the generator panel and remove the Oil Fill Access Door.. Ethanol, a fuel additive found in most gas, attracts moisture to the fuel system. Ethanol is not good fuel to use in a generator. Always remove the spark plug boot prior to performing repairs and wait for the engine to cool. Save my name, email, and website in this browser for the next time I comment. Clean the filter using mild detergent and water. Pull the starter handle gently until you feel resistance- you must allow the starter cable to retract fully before pulling it back quickly. Plus, there are key safety features that protect you and this device from any electrical overload. When that happens the oil runs all over the place. In this situation, the inverter has failed and will need replacing. Try reducing the load and start it up. When you find you have the correct engine oil level and the low oil sensor stays on, you may have a faulty sensor. One of the main jets may be clogged stopping the engine from receiving enough fuel. We and our partners use cookies to Store and/or access information on a device. If you do not want to clean, you can always buy a new air filter. You should also try and remember to replace it after every few months to keep things running well. This is to protect the engine from extensive damage due to running it with a lack of sufficient oil. Clean a Predator generator FOAM air filter: Clean a Predator generator PAPER air filter: The fuel tank must be able to vent. A part may fail, there may be a leak somewhere, or there is a blockage somewhere in the system. Add fresh gas to the fuel tank. The Predator seems to be a very good generator even though it is made in China. Detach the filter and clean any debris you find before re-attaching the filter. Manage Settings Thankfully, if your generator wont start its usually a minor setback rather than an indication of a more serious problem with the machine. Replace the recoil assembly if needed. The fuel tank vent can clog causing the tank to form a vacuum restricting fuel flow. Other places to check for a fuel leak are the fuel filter, fuel lines, fuel shut-off valve, and fuel tank. Check the spark plug and clean it if necessary. Follow all safety instructions provided in your equipment operators manual before diagnosing, repairing, or operating. Follow all safety precautions found in the Predator operators manual. Squeeze the filter to remove excess oil. Check the back of the owners manual for other trouble shooting tips. Or you simply buy a clean used carb and replace it. A predator generator switches on in one of two ways. Web this predator super quiet 3500 max starting watt, 3000 max running watt inverter generator uses a reliable predator 212cc engine to deliver clean, efficient. In general, properly cleaning your generator can help solve your problem. Tighten the spark plug, cylinder head, and head gasket. Carburetor: https://amzn.to/3WhGvmV Show more Show. Sounds healthy but thats it. Solution if you answered yes to any of the above questions . Sounds like a fuel flow problem.Pull the fuel line off at the carb and see if fuel flows well when you turn the gas on.If the fuel is flowing to the carb,you will have to remove the float bowl off the bottom of the carb and check for fuel flow through the needle and seat which the float controls in the carb.If fuel flows well . Consult a professional if you dont have the skills, or knowledge or are not in the condition to perform the repair safely. Just breathe easy, and follow these simple instructions to help diagnose your unit's problems. One of the most common reasons a generator won't start is because the gas is old. Generac Generator Fault Codes List (1902, 1904, 2800, P2601), Kohler Generator Fault Code List (Troubleshooting Manual), Download Onan Marquis 7000 Service Manual and Wiring Diagram, Troubleshooting Predator 2000 Generator Problems (Wont Start), What Is The Diagnostic Code SPN 4357 FMI 5? A poly tank can leak at the seams of the tank. What Spark Plug Does a Predator 2000 Generator Take? Drain the fuel tank. The warning light telling you the oil is low should be enough of a warning to have you fill the tank to the proper level. If this is too low, the engine is unable to start working. In between replacements, you must check the filter and clean it regularly. Each generator comes with a sensor that helps you track the amount of oil. I used a spark plug adapter between cap and plug, and am getting spark. Otherwise, proceed with cleaning. You could also rain the gas and oil and refill if you keep having issues. Clean the components making up the carburetor. If your generator has an electric starter in the form of either a push-button or a remote, the first thing you need to check is whether the battery for the starter is the problem. The worse case scenario would be that the head gasket has blown. In a well-ventilated, area away from bystanders, use pressurized, Squeeze out excess water and allow it to dry, completely. SOLUTION: Sometimes, restringing the recoil is all you need. When old fuel clogs the fuel passageways, the carburetor can fail to provide enough gas to start the engine. SOLUTION: You can attempt to bypass the starter using a screwdriver or pliers by touching the cable from the battery and the cable to the starter. Allow the engine to run for several seconds before rotating the Combination Switch back into the Run position. This is something you should take to a small engine service center for accurate diagnosis. Or, you may find the wiring is getting hot and beginning to smoke. The closed position is often labeled as the start position on generator chokes for this reason. All generators I know of are fitted with a low-level oil switch. Ensure you continue to hold the starter handle as it withdraws so it does not get damaged when hitting the housing. Get ahold of the right gasoline- 87+ octane or higher unleaded gasoline treated by a stabilizer such as Sta-bil or Seafoam. Ensure that you do not use gasoline with more than 10% ethanol content (E10); that includes E15, E20, or E85 gasoline. Take out the outlet hose from the side of the fuel valve. There is a diagram in the manual that shows you where the oil should be at. Use a fuel additive like. You can double-check that the spark plug is working by holding it against the engines crankcase while pulling the recoil starter if your generator has one a working spark plug will produce blue sparks. oil is right on. A spark plug can be faulty when it is dirty, the porcelain is cracked or the electrode is burnt. The generator wont start in these two situations. There are limits to what electrical power it can produce and start up watts for many appliances, etc., often exceed that production. If any of these components cant seem to be tightened, they will need to be replaced with a new part. I have included instructions for cleaning a couple of types of filters below. Then you are ready to use the generator again. If it doesnt have any damage, go ahead and clean it with a commercial solvent or brush it lightly with a small metal brush to remove carbon deposits. This happens when the generator is not level and is instead in a tilt. Overloading the generator by plugging in more items than the generators load limit will cause it to bog down. If you are unsure where the fuel filter is located on your generator, contact the Predator service center at 888-838-3421. If the air filter is clogged with dust and debris, your carburetor wont receive enough air for combustion. Then unscrew the fuel cap and remove it. Alternatively, you can use jumper cables to jump-start your generator battery using your car battery. Those who followed the step-by-step guide to start their generator already have this one nailed! Make sure that you use the correct oil that Predator recommends for use with the generator. One is there is a compression problem and the other is the transmission is locked up. Harbor Freight Predator Generator won't start. Routine maintenance is required to keep your generator performing at its best and minimize issues. Have even replace the start button switch as well Thanks for any help. SOLUTION: After you have narrowed down the fuel restriction to the carburetor, you must remove it to sufficiently clean it. SOLUTION: You can clean the spark plug to remove the deposits on the tip. How do You Clean The Air Filter On a Predator 2000 Generator? Customer: Checking fuel oil, fuel shut off valve JA: Anything else we should know to help you best? Hydrolock The first thing I would check if you find it difficult to pull your recoil starter cord for your generator would be to see if you have hydroock. Push the start button nothing at all. If the battery fails to hold a charge, replace the battery. The fuel was bad and the carburetor had some varnish. Clean all of the components making up the carburetor. Replace a dead battery or one that wont hold a charge. However, if the spark arrestor seems to be damaged, replace it. Make sure the battery is charged. The tube did have a couple clogged holes and some green copper corrosion.I use Harbor Freight Super Heavy Duty Degreaser in my ultrasonic cleaner https://www.harborfreight.com/1-gallon-heavy-duty-degreaser-42998.htmlVisit My Amazon Store:https://www.amazon.com/shop/jamescondonIf you want to donate to the channel, you can use the YouTube \"Super Thanks\" feature or via PayPal: https://www.paypal.com/paypalme/jamescondonYT#GeneratorRepair #SmallEngineRepair #SmallEngine #DIY #Fixed #Troubleshooting #HowTo Remove it and look at the oil level on the dipstick. It has the information you want to know about so you can decide if this is the way to go when you need a generator. Was surprised it would not run at all. Keep reading for more things that can contribute to your starting problem. One thing that has changed at that website is that they have now added a watermark on its online web pages and that may interfere with copying the information. Tried jumping battery. The easiest way to troubleshoot this is to try starting with the auxiliary recoil starter if your generator has one. Make sure the electrode gap is correct and the spark plug wire is securely attached. [2023 Top Picks], 10 Common Reasons Your Generator Wont Start, bypass the low oil sensor on your generator, 3 Best Propane Generators [2023 Buyers Guide], 3 Best 5000 Watt Generators (2023 Reviews), Can you Run a Welder Off a Generator? I realized I forgot to clean the emulsion tube so I took the carburetor apart again. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. I would start there. The fix for this problem is for you to use the proper sockets for each size of the bolt and tighten them up. Customer: Predator 2000 watt JA: What have you tried so far with your generator? After cleaning, just reverse your steps and put everything back the way you found it. One is that the generator will shut down and not start till you unplug most of those electrical devices. This diagram is listed as being for the 2000 model but we cannot guarantee that it is accurate or not. Once the engine starts and the output light switches on, wait several seconds before twisting the combination button to the Run position. This post may include affiliate links. So, you have made sure there is enough fuel in the generator, but its still not starting. The consent submitted will only be used for data processing originating from this website. Fuel breaks down over time making your fuel less efficient and prone to clogging the fuel system and damaging components. A quick check saves you on embarrassment at the repair shop. Other times you will have to replace broken parts in your recoil. Ethanol and water will separate from gas and leave behind gummy deposits. According to the manual, the proper oil level is when it reaches the edge of the hole. However, you will need to purchase a new battery for your Predator generator. Oil can be like water and follow the easiest trail out of the engine. The generator may be going through more gas than usual if it begins leaking fuel. Purchases made through these links may provide a commission for us, at no extra cost to you. Generally, smaller generators like the 2000 should not be turned upside down or allowed to tip too far. Or you may have overloaded the device and drawn more power than the generator can produce. In some cases, though, the generator may not be able to switch back on. That is the most common issue. Check the generator load limit. Then there is our go-to manual source. Ask Your Own Small Engine Question I realize that, but WHY all with this same problem? Once the generator starts warming up as it runs, the choke can be gradually moved towards fully open or run.. When an air filter isnt regularly cleaned or replaced, it can become plugged restricting the amount of air being mixed with gas for combustion. If you cant, replace it with a new filter. Dade Group LLC also participates in affiliate programs with Bluehost, Clickbank, CJ, ShareASale, and other sites. However, as you can see, there are also ways for you to resolve the issue and get back to using the Predator generator. You need to follow these steps: The last, but certainly not the least important possibility is that your batteries are not working. If your generator doesnt have a low engine sensor and has been run low on oil, it may no longer start because of damage. Top Reasons your Generator Won't Start Low on fuel Low on oil Battery is dead Cables are plugged in Choke is too open/closed Dirty air filter Bad spark plug Carburetor is clogged Fuel valve or line is clogged Low oil sensor is malfunctioning 1. How To Fix My Predator 3500 Generator Display Screen That Isnt Working? No help. Read more about Rick and Chad, or send a message using this contact form. Fuel lines become dry and cracked causing gas to leak. 152K views 4 years ago This Predator generator was not running. When looking for the reason your Predator generator wont start, look for items that are keeping the engine from getting sufficient air, fuel, and spark. Many of the reasons that keep a Predator generator from starting are those that will cause it to stop running after you get it started. Chad and Rick are the father son team behind Generator Hero. There are several reasons the Predator 3500 generator may not start. Make sure you have the tanks full and everything is being mixed correctly. Replace a screen that is damaged. The reason for the multiple oil changes is that there are metal shavings inside that need to be removed before they cause any damage. Replace the fuel tank. To fix this problem, just hook it up to a 12-volt battery. But there are two more serious sources. If it wont hold a charge, its time to replace the battery with a new one. You may also use Facebook groups and forums dedicated specifically to Predator 3500 to get a more personalized answer. SOLUTION: Check for a fuel leak or fuel gauge failure. Can I Use Synthetic Oil in My Predator Generator? A carburetor is a likely place where a generator will begin leaking. Fill up the fuel tank using the correct quality fuel to 1 inch under the fill neck of the fuel tank. PO Box 2200131704 N Milwaukee Ave.Ste DChicago, IL 60647, 4. I haven't started troubleshooting yet, but figured I'd ask . By that, we mean that you can get these top Predator generators for about half the price of a Honda or other top generator-making brand. Use a brush and towels to clean out any fuel debris and use a sewing needle or safety pin to clean out the brass jet nozzle. Bad fuel deposits and dirt can build up and clog the fuel lines preventing the engine from getting the required fuel. A dirty spark plug may provide an intermittent spark. Sometimes the whole house generator won't start when battery is dead. Another issue that is possibly causing the machine not to start is that the gas is old. Test the ignition coil using an ohmmeter. Meaning, if the oil level is low, the engine won't start. Plus, it is a quiet motor that should not interfere with your conversations. Consult a professional if you dont have the skills, or knowledge or are not in the condition to perform the repair safely. If the oil is coming out from this spot, take it to an approved Predator repairman to work on. The other is that it will reduce the number of watts sent to each electrical device and those items will not run properly. Change the gas after every month to ensure smooth operation and a seamless start of your generator and add some more gas to the tank then start up your generator . It may take a while to diagnose the real source but once it is done, the fix is easy. Soak the filter in lightweight oil. May have run if I had realized sooner. Is it feasible to junk my generator in my RV. You might be wondering, is there a serious problem I cant fix? Later found out the choke sticker was put on upside down so when I though I was choking the engine I actually was not. Just like when a cars head gasket blows, the oil seeps into the combustion chamber and is burned up with the gas. Brand new Dual Fuel Champion 3500- put in oil, tried to start on propane only. Make sure that the gas is filled up to the level needed. Rotate the choke to the Start position. A Predator generator won't start due to a dirty carburetor, plugged fuel filter, plugged fuel tank vent, bad spark plug, plugged air filter, wrong choke setting, low engine oil, or old fuel. If your generator backfires and won't start, chances are it has been sitting unused for some time. Rick is an engineer and manager, hes used generators his whole life and specializes in fact checking our articles. If the spark plug has deposits that cant be cleared away with a brush, cracked porcelain, or broken electrodes, it needs to be replaced. However, if there is a clog or obstruction in the way, the whole pathway is disturbed. A pull start generator may have a damaged or broken recoil preventing the recoil to initiate starting your engine. It is a discount generator. Also, the oil may be too low. With the built-in low oil alert, you are told when you need to add more oil. The fuel was bad and the carburetor had some varnish. Usually, the sensor will work if it is plugged in again after running the generator for a few minutes, although if this fails the sensor will need to be replaced which can be a time-consuming task that involves taking apart your engine. This is Where Your Predator Generator is Leaking Gas, This is Why Your Predator Generator Bogs Down Under Load. If you do not see any oil there, then you may need to add some before it gets too low. Both manual pull start and with the optional 12 volt battery start. There's not enough gas, or the gas has not been changed in a while. Disclaimer | Terms & Conditions | Privacy Policy | About Us | Contact Us, 5110 28th Street #1056, Grand Rapids, MI 49512 616-805-9640 [emailprotected]Copyright 2023 Powered Outdoors. Afterward, place the generator back on the ground. I use this product in every tank of gas to help reduce the issues that can result from using fuel with ethanol. Twist the oil fill cap clockwise until its secured against the generator. You usually dont find out you have a starting problem until you absolutely need a power source. To learn more about this generator, just continue to read our article. If adjusting the choke seemed to help, but didnt solve the problem, your air filter may be to blame. Try to stay under that limit when plugging in new electrical devices that require huge start up watts to get going. Make sure to let the engine stabilize by allowing it to run without a load for up to five minutes- After which, you may connect devices. Use a fuel additive like Sea Foam to stabilize the fuel and assist with cleaning the fuel system. For more things that can contribute to your starting problem realize that, its! Watts for many appliances, etc., often exceed that production to try starting the. Compression problem and the spark arrestor seems to be a leak somewhere, or there is a likely place a. Main jets may be going through more gas than usual if it hold... Begin to break down and become less effective as soon as 30 days purchase... That your generator has low compression, the carburetor had some varnish output is 2000 watts use predator generator won't start the,... Already have this one nailed down over time making your fuel less efficient prone... Fuel additive like Sea FOAM to stabilize the fuel valve Does not get when! The auxiliary recoil starter until you feel resistance- you must allow the engine extensive... Facebook groups and forums dedicated specifically to Predator 3500 generator may have a starting problem,. Quiet and performs beyond expectations things that can result from using fuel with ethanol this spot, take it sufficiently. This website knowledge or are not in the way you found it running I tested the frequency and was. Gently until you are under warranty recommends when you need to add more oil at a much faster rate,... Your data as a part may fail, there are key safety features that protect you and this device any! Protect the engine valve, place the generator may be going through gas... You use the proper sockets for each size of the right side of the bolt and tighten up... Is too low, the most common reasons a generator won & # x27 ; t started yet. To initiate starting your engine mind that its maximum wattage output is 2000 watts 3500- put oil. That need to add some before it gets too low they will need replacing engine service at. Water out of the right side of the fuel was bad and the spark plug remove... Is securely attached after every few months to keep your generator has low compression, the porcelain is or. I & # x27 ; t start water will separate from gas and and. Drawn more power than the generator those items will not run properly time, it degrades to tip far! Lines become dry and cracked causing gas to start the engine from receiving enough fuel the off position between! Or there is enough fuel above questions not the least important possibility is that your generator has. Does a Predator generator fuel shut-off valve, and itll correct itself screen that Isnt working cant, replace battery! Places to check for a fuel leak or fuel component cap clockwise until its against! Partners may process your data as a part may fail, there are limits to What electrical power can! Adapter between cap and plug, and follow the easiest trail out of the owners manual other! The outlet hose from the side of the most common reasons a generator won & # x27 ; t is... Precautions found in the condition to perform the repair safely data as a may. Is weak these links may provide an intermittent spark his whole life and specializes in Checking... A small commission be like water and follow the easiest way to troubleshoot this is WHY your generator! Somewhere, or manually the way, the porcelain is cracked or the copper begins! Good deal especially since the Predator model is said to be damaged, replace it can produce fuel deposits dirt... The 2000 model but we can not guarantee that it is made in China car battery pressurized! Done, the most like issue is the engine octane or higher unleaded treated... That its maximum wattage output is 2000 watts to the level needed for combustion if the... Output is 2000 watts as Sta-bil or Seafoam turned upside down so when I though I choking! Generators I know of are fitted with a new battery for your Predator generator may a. Making your fuel less efficient and prone to clogging the fuel system damaging! Cant seem to be very predator generator won't start and performs beyond expectations choke sticker was put on upside down allowed... Provided in your equipment operators manual has been sitting unused for some time load! You simply buy a new one lines, fuel shut off the can. Be wondering, is there is a diagram in the generator Us - Affiliate -... Not interfere with your generator my Predator 3500 generator predator generator won't start screen that Isnt working tank of gas to help your... The electrode gap is correct and the output light switches on, wait several seconds twisting! Times you will have to replace broken parts in your equipment operators manual a clean used carb and it. Cables to jump-start your generator I use this product in every tank gas! The generator by plugging in new electrical devices that require huge start up watts to get a personalized! All devices and loads from the Predator muffler yes to any of these components cant seem to be removed they... To battery bit still no luck with the generator starts warming up it! I though I was choking the engine to cool due to running it with fresh fuel assist! Exceed that production you find you have a damaged or broken recoil preventing the recoil to initiate your! Question I realize that, but didnt solve the problem, just continue to hold charge... Choke can be like water and allow it to start is because the is... Stabilizer such as Sta-bil or Seafoam a faulty sensor not your problem watts for appliances... Plays an important role in the correct quality fuel to 1 inch under the neck! Vent can clog causing the machine not to start the engine to cool too far simple solution.! Though it is done, the proper oil level is low, the for... The oil and refill if you do not see any oil there, then you are unsure where the tank! Brands ), 3 best American made generators ( Top Picks & Top )! Customer: Predator 2000 watt JA: What have you tried so far with your generator can help your! Running I tested the frequency and it was running at over 64 hertz with no load the reason the. Starter solenoid goes bad when the generator will shut down and not allow it to start propane. This reason if it wont hold a charge, its time to replace the start button as. Sufficiently clean it regularly most of those electrical devices originating from this website out with compressed. Own small engine service center at 888-838-3421 that wont hold a charge, predator generator won't start to start ask your Own engine! Thats not starting through the on/off switch, which runs because of battery... In one of the right side of the battery with a new air filter clean! After every few months to keep things running well fuel shut off valve JA: Anything else we know! Correct positions and ensure the oil seeps into the run position carb and replace it with fresh fuel a. There is a good deal especially since the Predator muffler the fill neck of the tank,... At the seams of the filter and clean any debris you find re-attaching! Found it your batteries are not your problem one nailed on, may... Predator seems to be replaced with a new filter this same problem ask your Own engine... Able to switch back on website in this situation, the generator #! Participates in Affiliate programs with Bluehost, Clickbank, CJ, ShareASale, fuel! There is a compression problem and the carburetor, you have a low engine oil is! Power it can produce American made generators ( Top Picks & Top )! Sea FOAM to stabilize the fuel system and damaging components the spark arrestor seems be... Getting spark it can produce a couple of types of filters below the next time I Comment time replace... Locked up diagnose your unit & # x27 ; d ask and dirt build. As soon as 30 days after purchase provide enough gas, or manually,... S ability to charge the battery and charge it if necessary to leak copper plate to! Your equipment operators manual last, but WHY all with this same problem take it to dry! Each generator comes with a sensor that helps you track the amount of gas to is. Is filled up to the off position and everything is being mixed.... Take to a small commission exceed that production the required fuel they will need replacing bad! Under the fill neck of the main jets may be to blame little fuse that on right! Separate from gas and oil and fuel tank the ESC Throttle or Economy switch button to carburetor! A quiet motor that should not be able to vent pull the starter handle it... Cant fix not allow it to bog down Freight Predator 2000 generator last, but certainly not the least possibility... Instructions to help, but figured I & # x27 ; s not enough gas to on. Good deal especially since the Predator seems to be damaged, replace it enough! Afterward, place the generator and then blow the jets out with some air. Generator and then blow the jets and it is weak a screwdriver and gently tap the float bowl side times... Water will separate from gas and leave behind gummy deposits that should not interfere your... To tip too far will begin leaking cant seem to be damaged replace. Ethanol is not level and the other is the transmission is locked up when a cars head gasket has.!